Capillary Flow Porometer

Model: iCFP-1100 / iCFP-1200 / iCFP-1500

  • iCFP is a new generation Porometer of Capillary Flow Porometer based on gas-liquid displacement method (ASTM-F316)
  • Non-destructive nature of testing
  • Fully automated & computer controlled operations
  • Testing of small samples as well as complete parts
  • Use of many non-wetting liquid (Example: Water, Alcohol, Silwet solution & Galwet solution)

Download Brochure

- +

Benefits

According to ASTM F316-03

  • Where a nontoxic wetting liquid can spontaneously fill the pores in the sample and a non reacting Liquid can displace liquid from pores.
  • First the largest pores will get emptied, as they require lower pressure than smaller pores.
  • As the pressure is increased, more and more smaller pores are progressively emptied.
  • The pressure and flow rate of Liquid through the emptied pores provides the through pore distribution. The pressure at which through pores empty is inversely proportional to the pore size.
  • Through pores are the pores connected from one side of material to the other side. Innova Porometer measures the pore throat diameter, which is the most constricted part of the entire pore path.

Specifications

Specifications

Model Innova iCFP-1100 Innova iCFP-1200 Innova iCFP-1500
Pressure range 100psi 200psi 500psi
Pressure Transducer Accuracy Accuracy: 0.05% of Reading

Resolution: 0.000017

Maximum pore 500μm 500μm 500μm
Minimum Pore 0.06μm 0.03μm 0.013μm
Sample size Dia. ≤ 60mm and Thickness upto 10mm
Sample Geometry Flat Sheets, Rods, Tubes, Hollow Fibers, Cartridges….
Pressure Regulator Single Dual, Auto switch Dual, Auto switch
Gas flow range 0-200 L/min

0-10 L/min (optional)

0-200 L/min

0-10 L/min (optional)

0-200 L/min

0-10 L/min (optional)

Flow Control Automatic, 0-30cc / 0-100cc / 0-500cc ; Resolution: 0.00025
Data transfer External PC or Build-in Touch panel PC
Operation Automatic test mode and manual operate mode
Test Type Gas-Liquid Method

Pore Size Distribution

Bubble Point

Gas Permeability

Cumulative Flow Distribution

Total Pore Number

Total Pore Area

Liquid Permeability (optional)

Pressurized gas Clean and dry gas, such as air and nitrogen gas.

Air Compressor or Gas cylinders

Applications

Applications

Non-woven, Electrospinning, Glass fiber, Filter paper, Membrane-MF/UF/NF, Hollow fiber, Hemodialysis, Ceramic, Sintered metal, PTFE, Battery Separator, Fuel cell GDL